Search results for "EXTERNAL MATRIX"

showing 4 items of 4 documents

Study of mycotoxin calibration approaches on the example of trichothecenes analysis from flour

2012

The aim of this study was to evaluate the applicability of different calibration approaches in trichothecenes analysis from wheat flour. Concretely eight trichothecenes (five type B trichothecenes and three type A trichothecenes) were analyzed by matrix solid-phase dispersion (MSPD) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). In the first set of experiments the presence of matrix effects was evaluated; values ranged between 59% and 79%. In the second set of experiments, solutions to compensate these signal suppressions were examined. Different calibration methods showed to tackle matrix effects obtaining values between 69% and 85% for external matrix matched calibration a…

FlourWheat flourAnalytical chemistryToxicologyMass spectrometryMatrix (chemical analysis)chemistry.chemical_compoundTandem Mass SpectrometryCalibrationControl materialExternal matrix-matched calibrationMycotoxinReference standardsChromatography High Pressure LiquidTriticumInternal standard calibrationChromatographyMass spectrometryMatrix matched calibrationGeneral MedicineReference StandardsMycotoxinsDeuteriumchemistryCalibrationIndicators and ReagentsTrichothecenesFood Science
researchProduct

Application of an HPLC-MS/MS method for mycotoxin analysis in commercial baby foods

2012

Abstract This article describes the validation of an analytical method for the detection of 21 mycotoxins in baby food. The analytical method is based on the simultaneous extraction of selected mycotoxins by matrix solid-phase dispersion (MSPD) followed by liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) using a hybrid triple quadrupole-linear ion trap mass spectrometer (QTRAP®). Information Dependent Acquisition (IDA), an extra confirmation tool for samples that contain the selected mycotoxins, was used. The matrix effects were evaluated, and the corrections for the matrix effects were performed using two calibration approaches: external matrix-matched calibration and…

Internal standard calibrationChromatographyChemistryBaby foodExtraction (chemistry)food and beveragesGeneral MedicineMycotoxinsTandem mass spectrometryAnalytical ChemistryMatrix (chemical analysis)Baby foodchemistry.chemical_compoundMSPDCalibrationmedia_common.cataloged_instanceIon trapEuropean unionExternal matrix-matched calibrationMycotoxinQTRAPFood Sciencemedia_commonFood Chemistry
researchProduct

Myoglobin embedded in saccharide amorphous matrices: water-dependent domains evidenced by small angle X-ray scattering

2010

We report Small Angle X-ray Scattering (SAXS) measurements performed on samples of carboxy-myoglobin (MbCO) embedded in low-water trehalose glasses. Results showed that, in such samples, "low-protein" trehalose-water domains are present, surrounded by a protein-trehalose-water background; such finding is supported by Infrared Spectroscopy (FTIR) measurements. These domains, which do not appear in the absence of the protein and in analogous sucrose systems, preferentially incorporate the incoming water at the onset of rehydration, and disappear following large hydration. This observation suggests that, in organisms under anhydrobiosis, analogous domains could play a buffering role against th…

Photosynthetic reaction centreSucroseGLASS-TRANSITIONGeneral Physics and AstronomyInfrared spectroscopyRhodobacter sphaeroideschemistry.chemical_compoundRhodobacter sphaeroidesScattering Small AngleSpectroscopy Fourier Transform InfraredPHOSPHOLIPID-BILAYERREACTION CENTERSPhysical and Theoretical ChemistrySettore CHIM/02 - Chimica FisicabiologyScatteringSmall-angle X-ray scatteringMyoglobinTrehaloseWaterbiology.organism_classificationPROTEIN DYNAMICSTrehaloseMOLECULAR-DYNAMICS SIMULATIONAmorphous solidCrystallographyMyoglobinchemistryTHERMAL-DENATURATIONNEUTRON-SCATTERINGCARBOXY-MYOGLOBINEXTERNAL MATRIXTREHALOSE-COATED MBCO
researchProduct

Elastic neutron scattering of dry and rehydrated trehalose coated carboxy-myoglobin

2008

We report here a comparison between the hydrogen atoms mean square displacements measured by elastic neutron scattering on trehalose coated carboxy-myoglobin, at ILL on the backscattering spectrometers IN13 and IN16. An inconsistency is observed when comparing the mean square displacements measured on the two spectrometer, on samples of identical composition, since they resulted of larger amplitude on IN13 (either in condition of drought or after overnight rehydration under 75% D2O atmosphere), notwithstanding the lower time window accessible on this instrument with respect to IN16. Such inconsistency disappears when the data obtained on this last spectrometer are analyzed in two separate r…

SpectrometerHydrogenChemistryEnthalpyAnalytical chemistryPROTEINGeneral Physics and Astronomychemistry.chemical_elementNeutron scatteringMOLECULAR-DYNAMICS SIMULATIONTrehalosechemistry.chemical_compoundROOM-TEMPERATUREAmplitudeMyoglobinWATEREXTERNAL MATRIXWave vectorPhysical and Theoretical Chemistryneutron-scattering trehalose myoglobin
researchProduct